services: Add apcupsd-service-type.
* gnu/services/power.scm: New file.
* gnu/local.mk (GNU_SYSTEM_MODULES): Add it.
* doc/guix.texi (Power Management Services): Document service and data types.
Change-Id: If205d19bea1d20a99309626e28521a2d6fe6702f
Signed-off-by: Maxim Cournoyer <[email protected]>
Reviewed-by: Maxim Cournoyer <[email protected]>
Diffstat (limited to 'doc/guix.texi')
-rw-r--r-- | doc/guix.texi | 382 |
1 files changed, 379 insertions, 3 deletions
diff --git a/doc/guix.texi b/doc/guix.texi index 9f5a776202..9764b8b99a 100644 --- a/doc/guix.texi +++ b/doc/guix.texi @@ -123,7 +123,7 @@ Copyright @copyright{} 2023 Foundation Devices, Inc.@* Copyright @copyright{} 2023 Thomas Ieong@* Copyright @copyright{} 2023 Saku Laesvuori@* Copyright @copyright{} 2023 Graham James Addis@* -Copyright @copyright{} 2023, 2024 Tomas Volf@* +Copyright @copyright{} 2023-2025 Tomas Volf@* Copyright @copyright{} 2024, 2025 Herman Rimm@* Copyright @copyright{} 2024 Matthew Trzcinski@* Copyright @copyright{} 2024 Richard Sent@* @@ -422,7 +422,7 @@ Services * Network File System:: NFS related services. * Samba Services:: Samba services. * Continuous Integration:: Cuirass and Laminar services. -* Power Management Services:: Extending battery life. +* Power Management Services:: Extending battery life, etc. * Audio Services:: The MPD. * Virtualization Services:: Virtualization services. * Version Control Services:: Providing remote access to Git repositories. @@ -19287,7 +19287,7 @@ declaration. * Network File System:: NFS related services. * Samba Services:: Samba services. * Continuous Integration:: Cuirass and Laminar services. -* Power Management Services:: Extending battery life. +* Power Management Services:: Extending battery life, etc. * Audio Services:: The MPD. * Virtualization Services:: Virtualization services. * Version Control Services:: Providing remote access to Git repositories. @@ -36891,6 +36891,382 @@ packages linux)} module @end table @end deftp +The @code{(gnu services power)} module provides a service definition for +@uref{http://www.apcupsd.org/, apcupsd}, a utility to interact with +@acronym{APC, APC by Schneider Electric or formerly American Power +Conversion Corporation} @acronym{UPS, Uninterruptible Power Supply} +devices. Apcupsd also works with some @acronym{OEM, Original Equipment +Manufacturer}-branded products manufactured by APC. + +@defvar apcupsd-service-type +The service type for apcupsd. For USB UPSes no configuration is +necessary, however tweaking some fields to better suit your needs might +be desirable. The defaults are taken from the upstream configuration +and they are not very conservative (for example, the default +@code{battery-level} of 5% may be considered too low by some). + +The default event handlers do send emails, read more in +@ref{apcupsd-event-handlers}. + +@lisp +(service apcupsd-service-type) +@end lisp +@end defvar + +@deftp {Data Type} apcupsd-configuration + +Available @code{apcupsd-configuration} fields are: + +@table @asis +@item @code{apcupsd} (default: @code{apcupsd}) (type: package) +The @code{apcupsd} package to use. + +@item @code{shepherd-service-name} (default: @code{apcupsd}) (type: symbol) +The name of the shepherd service. You can add the service multiple +times with different names to manage multiple UPSes. + +@item @code{auto-start?} (default: @code{#t}) (type: boolean) +Should the shepherd service auto-start? + +@item @code{pid-file} (default: @code{"/var/run/apcupsd.pid"}) (type: string) +The file name of the pid file. + +@item @code{debug-level} (default: @code{0}) (type: integer) +The logging verbosity. Bigger number means more logs. The source code +uses up to @code{300} as debug level value, so a value of @code{999} +seems reasonable to enable all the logs. + +@item @code{run-dir} (default: @code{"/var/run/apcupsd"}) (type: string) +The directory containing runtime information. You need to change this +if you desire to run multiple instances of the daemon. + +@item @code{name} (type: maybe-string) +Use this to give your UPS a name in log files and such. This is +particularly useful if you have multiple UPSes. This does not set the +EEPROM. It should be 8 characters or less. + +@item @code{cable} (default: @code{usb}) (type: enum-cable) +The type of a cable connecting the UPS to your computer. Possible +generic choices are @code{'simple}, @code{'smart}, @code{'ether} and +@code{'usb}. + +Alternatively, a specific cable model number may be used: +@code{'940-0119A}, @code{'940-0127A}, @code{'940-0128A}, +@code{'940-0020B}, @code{'940-0020C}, @code{'940-0023A}, +@code{'940-0024B}, @code{'940-0024C}, @code{'940-1524C}, +@code{'940-0024G}, @code{'940-0095A}, @code{'940-0095B}, +@code{'940-0095C}, @code{'940-0625A}, @code{'M-04-02-2000}. + +@item @code{type} (default: @code{usb}) (type: enum-type) +The type of the UPS you have. + +@table @code +@item apcsmart +Newer serial character device, appropriate for SmartUPS models using a +serial cable (not an USB). + +@item usb +Most new UPSes are an USB. + +@item net +Network link to a master apcupsd through apcupsd's Network Information +Server. This is used if the UPS powering your computer is connected to +a different computer for monitoring. + +@item snmp +SNMP network link to an SNMP-enabled UPS device. + +@item netsnmp +Same as the SNMP above but requires use of the net-snmp library. Unless +you have a specific need for this old driver, you should use the +@code{'snmp} instead. + +@item dumb +An old serial character device for use with simple-signaling UPSes. + +@item pcnet +A PowerChute Network Shutdown protocol which can be used as an +alternative to an SNMP with the AP9617 family of smart slot cards. + +@item modbus +A serial device for use with newest SmartUPS models supporting the +MODBUS protocol. + +@end table + +@item @code{device} (default: @code{""}) (type: string) +For USB UPSes, usually you want to set this to an empty string (the +default). For other UPS types, you must specify an appropriate port or +address. + +@table @code +@item apcsmart +Set to the appropriate @file{/dev/tty**} device. + +@item usb +A null string setting enables auto-detection, which is the best choice +for most installations. + +@item net +Set to @code{@var{hostname}:@var{port}}. + +@item snmp +Set to @code{@var{hostname}:@var{port}:@var{vendor}:@var{community}}. +The @var{hostname} is the ip address or hostname of the UPS on the +network. The @var{vendor} can be can be "APC" or "APC_NOTRAP". +"APC_NOTRAP" will disable SNMP trap catching; you usually want "APC". +The @var{port} is usually 161. The @var{community} is usually +"private". + +@item netsnmp +Same as the @code{'snmp}. + +@item dumb +Set to the appropriate @file{/dev/tty**} device. + +@item pcnet +Set to @code{@var{ipaddr}:@var{username}:@var{passphrase}:@var{port}}. +The @var{ipaddr} is the IP address of the UPS management card. The +@var{username} and the @var{passphrase} are the credentials for which +the card has been configured. The @var{port} is the port number on +which to listen for messages from the UPS, normally 3052. If this +parameter is empty or missing, the default of 3052 will be used. + +@item modbus +Set to the appropriate @file{/dev/tty**} device. You can also leave it +empty for MODBUS over USB or set to the serial number of the UPS. + +@end table + +@item @code{poll-time} (default: @code{60}) (type: integer) +The interval (in seconds) at which apcupsd polls the UPS for status. +This setting applies both to directly-attached UPSes (apcsmart, usb, +dumb) and networked UPSes (net, snmp). Lowering this setting will +improve the apcupsd's responsiveness to certain events at the cost of +higher CPU utilization. + +@item @code{on-batery-delay} (default: @code{6}) (type: integer) +The time in seconds from when a power failure is detected until we react +to it with an onbattery event. The @code{'powerout} event will be +triggered immediately when a power failure is detected. However, the +@code{'onbattery} event will be trigger only after this delay. + +@item @code{battery-level} (default: @code{5}) (type: integer) +If during a power failure, the remaining battery percentage (as reported +by the UPS) is below or equal to this value, the apcupsd will initiate a +system shutdown. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation + +@item @code{remaining-minutes} (default: @code{3}) (type: integer) +If during a power failure, the remaining runtime in minutes (as +calculated internally by the UPS) is below or equal to this value, +apcupsd will initiate a system shutdown. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation + +@item @code{timeout} (default: @code{0}) (type: integer) +If during a power failure, the UPS has run on batteries for this many +seconds or longer, apcupsd will initiate a system shutdown. The value +of 0 disables this timer. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation + +@item @code{annoy-interval} (default: @code{300}) (type: integer) +The time in seconds between annoying users (via the @code{'annoyme} +event) to sign off prior to system shutdown. 0 disables. + +@item @code{annoy-delay} (default: @code{60}) (type: integer) +The initial delay in seconds after a power failure before warning users +to get off the system. + +@item @code{no-logon} (default: @code{disable}) (type: enum-no-logon) +The condition which determines when users are prevented from logging in +during a power failure. + +@item @code{kill-delay} (default: @code{0}) (type: integer) +If this is non-zero, the apcupsd will continue running after a shutdown +has been requested, and after the specified time in seconds attempt to +kill the power. This is for use on systems where apcupsd cannot regain +control after a shutdown. + +@item @code{net-server} (default: @code{#f}) (type: boolean) +If enabled, a network information server process will be started. + +@item @code{net-server-ip} (default: @code{"127.0.0.1"}) (type: string) +An IP address on which the NIS server will listen for incoming +connections. + +@item @code{net-server-port} (default: @code{3551}) (type: integer) +An IP port on which the NIS server will listen for incoming connections. + +@item @code{net-server-events-file} (type: maybe-string) +If you want the last few EVENTS to be available over the network by the +network information server, you must set this to a file name. + +@item @code{net-server-events-file-max-size} (default: @code{10}) (type: integer) +The maximum size of the events file in kilobytes. + +@item @code{class} (default: @code{standalone}) (type: enum-class) +Normally standalone unless you share an UPS using an APC ShareUPS card. + +@item @code{mode} (default: @code{disable}) (type: enum-mode) +Normally disable unless you share an UPS using an APC ShareUPS card. + +@item @code{stat-time} (default: @code{0}) (type: integer) +The time interval in seconds between writing the status file, 0 +disables. + +@item @code{log-stats} (default: @code{#f}) (type: boolean) +Also write the stats as a logs. This generates a lot of output. + +@item @code{data-time} (default: @code{0}) (type: integer) +The time interval in seconds between writing the data records to the log +file, 0 disables. + +@item @code{facility} (type: maybe-string) +The logging facility for the syslog. + +@item @code{event-handlers} (type: apcupsd-event-handlers) +Handlers for events produced by apcupsd. + +@end table +@end deftp + +@anchor{apcupsd-event-handlers} +@deftp {Data Type} apcupsd-event-handlers + +For a description of the events please refer to @samp{man 8 apccontrol}. + +Each handler shall be a gexp. It is spliced into the control script for +the daemon. In addition to the standard Guile programming environment, +the following procedures and variables are also available: + +@table @code +@item conf +Variable containing the file name of the configuration file. + +@item powerfail-file +Variable containing the file name of the powerfail file. + +@item cmd +The event currently being handled. + +@item name +The name of the UPS as specified in the configuration file. + +@item connected? +Is @code{#t} if @command{apcupsd} is connected to the UPS via a serial +port (or a USB port). In most configurations, this will be the case. +In the case of a Slave machine where apcupsd is not directly connected +to the UPS, this value will be @code{#f}. + +@item powered? +Is @code{#t} if the computer on which @command{apcupsd} is running is +powered by the UPS and @code{#f} if not. At the moment, this value is +unimplemented and always @code{#f}. + +@item (err @var{fmt} @var{args...}) +Wrapper around @code{format} outputting to @code{(current-error-port)}. + +@item (wall @var{fmt} @var{args...}) +Wrapper around @code{format} outputting via @command{wall}. + +@item (apcupsd @var{args...}) +Call @command{apcupsd} while passing the correct configuration file and +all the arguments. + +@item (mail-to-root @var{subject} @var{body}) +Send an email to the local administrator. This procedure assumes the +@command{sendmail} is located at @command{/run/privileged/bin/sendmail} +(as would be the case with @code{opensmtpd-service-type}). + +@end table + +Available @code{apcupsd-event-handlers} fields are: + +@table @asis +@item @code{modules} (type: gexp) +Additional modules to import into the generated handler script. + +@item @code{killpower} (type: gexp) +The handler for the killpower event. + +@item @code{commfailure} (type: gexp) +The handler for the commfailure event. + +@item @code{commok} (type: gexp) +The handler for the commfailure event. + +@item @code{powerout} (type: gexp) +The handler for the powerout event. + +@item @code{onbattery} (type: gexp) +The handler for the onbattery event. + +@item @code{offbattery} (type: gexp) +The handler for the offbattery event. + +@item @code{mainsback} (type: gexp) +The handler for the mainsback event. + +@item @code{failing} (type: gexp) +The handler for the failing event. + +@item @code{timeout} (type: gexp) +The handler for the timeout event. + +@item @code{loadlimit} (type: gexp) +The handler for the loadlimit event. + +@item @code{runlimit} (type: gexp) +The handler for the runlimit event. + +@item @code{doreboot} (type: gexp) +The handler for the doreboot event. + +@item @code{doshutdown} (type: gexp) +The handler for the doshutdown event. + +@item @code{annoyme} (type: gexp) +The handler for the annoyme event. + +@item @code{emergency} (type: gexp) +The handler for the emergency event. + +@item @code{changeme} (type: gexp) +The handler for the changeme event. + +@item @code{remotedown} (type: gexp) +The handler for the remotedown event. + +@item @code{startselftest} (type: gexp) +The handler for the startselftest event. + +@item @code{endselftest} (type: gexp) +The handler for the endselftest event. + +@item @code{battdetach} (type: gexp) +The handler for the battdetach event. + +@item @code{battattach} (type: gexp) +The handler for the battattach event. + +@end table +@end deftp + @node Audio Services @subsection Audio Services |