services: Add apcupsd-service-type.
* gnu/services/power.scm: New file.
* gnu/local.mk (GNU_SYSTEM_MODULES): Add it.
* doc/guix.texi (Power Management Services): Document service and data types.
Change-Id: If205d19bea1d20a99309626e28521a2d6fe6702f
Signed-off-by: Maxim Cournoyer <[email protected]>
Reviewed-by: Maxim Cournoyer <[email protected]>
Diffstat (limited to 'gnu')
-rw-r--r-- | gnu/local.mk | 1 | ||||
-rw-r--r-- | gnu/services/power.scm | 669 |
2 files changed, 670 insertions, 0 deletions
diff --git a/gnu/local.mk b/gnu/local.mk index 09b29da79f..f1a3ee2b4b 100644 --- a/gnu/local.mk +++ b/gnu/local.mk @@ -765,6 +765,7 @@ GNU_SYSTEM_MODULES = \ %D%/services/nix.scm \ %D%/services/nfs.scm \ %D%/services/pam-mount.scm \ + %D%/services/power.scm \ %D%/services/science.scm \ %D%/services/security.scm \ %D%/services/security-token.scm \ diff --git a/gnu/services/power.scm b/gnu/services/power.scm new file mode 100644 index 0000000000..68a67e63e8 --- /dev/null +++ b/gnu/services/power.scm @@ -0,0 +1,669 @@ +;;; Copyright © 2025 Tomas Volf <[email protected]> + +;;;; Commentary: + +;;; Power-related services. + +;;;; Code: + +(define-module (gnu services power) + #:use-module (gnu) + #:use-module (gnu packages admin) + #:use-module (gnu packages linux) + #:use-module (gnu packages power) + #:use-module (gnu services configuration) + #:use-module (gnu services shepherd) + #:use-module (gnu services) + #:use-module (guix packages) + #:use-module (guix records) + #:use-module (ice-9 match) + #:use-module (srfi srfi-1) + #:use-module (srfi srfi-26) + #:export (apcupsd-service-type + + apcupsd-configuration + apcupsd-configuration-apcupsd + apcupsd-configuration-shepherd-service-name + apcupsd-configuration-auto-start? + apcupsd-configuration-pid-file + apcupsd-configuration-debug-level + apcupsd-configuration-run-dir + apcupsd-configuration-name + apcupsd-configuration-cable + apcupsd-configuration-type + apcupsd-configuration-device + apcupsd-configuration-poll-time + apcupsd-configuration-on-batery-delay + apcupsd-configuration-battery-level + apcupsd-configuration-remaining-minutes + apcupsd-configuration-timeout + apcupsd-configuration-annoy-interval + apcupsd-configuration-annoy-delay + apcupsd-configuration-no-logon + apcupsd-configuration-kill-delay + apcupsd-configuration-net-server + apcupsd-configuration-net-server-ip + apcupsd-configuration-net-server-port + apcupsd-configuration-net-server-events-file + apcupsd-configuration-net-server-events-file-max-size + apcupsd-configuration-class + apcupsd-configuration-mode + apcupsd-configuration-stat-time + apcupsd-configuration-log-stats + apcupsd-configuration-data-time + apcupsd-configuration-facility + apcupsd-configuration-event-handlers + + apcupsd-event-handlers + apcupsd-event-handlers-modules + apcupsd-event-handlers-annoyme + apcupsd-event-handlers-battattach + apcupsd-event-handlers-battdetach + apcupsd-event-handlers-changeme + apcupsd-event-handlers-commfailure + apcupsd-event-handlers-commok + apcupsd-event-handlers-doreboot + apcupsd-event-handlers-doshutdown + apcupsd-event-handlers-emergency + apcupsd-event-handlers-endselftest + apcupsd-event-handlers-failing + apcupsd-event-handlers-killpower + apcupsd-event-handlers-loadlimit + apcupsd-event-handlers-mainsback + apcupsd-event-handlers-offbattery + apcupsd-event-handlers-onbattery + apcupsd-event-handlers-powerout + apcupsd-event-handlers-remotedown + apcupsd-event-handlers-runlimit + apcupsd-event-handlers-startselftest + apcupsd-event-handlers-timeout)) + +(define-configuration/no-serialization apcupsd-event-handlers + (modules + (gexp #~()) + "Additional modules to import into the generated handler script.") + (killpower + (gexp + #~((wall "Apccontrol doing: apcupsd --killpower on UPS ~a" name) + (sleep 10) + (apcupsd "--killpower") + (wall "Apccontrol has done: apcupsd --killpower on UPS ~a" name))) + "The handler for the killpower event.") + (commfailure + (gexp + #~((let ((msg (format #f "~a Communications with UPS ~a lost." + (gethostname) name))) + (mail-to-root msg msg)) + (wall "Warning: communications lost with UPS ~a" name))) + "The handler for the commfailure event.") + (commok + (gexp + #~((let ((msg (format #f "~a Communications with UPS ~a restored." + (gethostname) name))) + (mail-to-root msg msg)) + (wall "Communications restored with UPS ~a" name))) + "The handler for the commfailure event.") + (powerout + (gexp + #~(#t)) + "The handler for the powerout event.") + (onbattery + (gexp + #~((let ((msg (format #f "~a UPS ~a Power Failure !!!" + (gethostname) name))) + (mail-to-root msg msg)) + (wall "Power failure on UPS ~a. Running on batteries." name))) + "The handler for the onbattery event.") + (offbattery + (gexp + #~((let ((msg (format #f "~a UPS ~a Power has returned." + (gethostname) name))) + (mail-to-root msg msg)) + (wall "Power has returned on UPS ~a..." name))) + "The handler for the offbattery event.") + (mainsback + (gexp + #~((when (file-exists? powerfail-file) + (wall "Continuing with shutdown.")))) + "The handler for the mainsback event.") + (failing + (gexp + #~((wall "Battery power exhausted on UPS ~a. Doing shutdown." name))) + "The handler for the failing event.") + (timeout + (gexp + #~((wall "Battery time limit exceeded on UPS ~a. Doing shutdown." name))) + "The handler for the timeout event.") + (loadlimit + (gexp + #~((wall "Remaining battery charge below limit on UPS ~a. Doing shutdown." name))) + "The handler for the loadlimit event.") + (runlimit + (gexp + #~((wall "Remaining battery runtime below limit on UPS ~a. Doing shutdown." name))) + "The handler for the runlimit event.") + (doreboot + (gexp + #~((wall "UPS ~a initiating Reboot Sequence" name) + (system* #$(file-append shepherd "/sbin/reboot")))) + "The handler for the doreboot event.") + (doshutdown + (gexp + #~((wall "UPS ~a initiated Shutdown Sequence" name) + (system* #$(file-append shepherd "/sbin/halt")))) + "The handler for the doshutdown event.") + (annoyme + (gexp + #~((wall "Power problems with UPS ~a. Please logoff." name))) + "The handler for the annoyme event.") + (emergency + (gexp + #~((wall "Emergency Shutdown. Possible battery failure on UPS ~a." name))) + "The handler for the emergency event.") + (changeme + (gexp + #~((let ((msg (format #f "~a UPS ~a battery needs changing NOW." + (gethostname) name))) + (mail-to-root msg msg)) + (wall "Emergency! Batteries have failed on UPS ~a. Change them NOW." name))) + "The handler for the changeme event.") + (remotedown + (gexp + #~((wall "Remote Shutdown. Beginning Shutdown Sequence."))) + "The handler for the remotedown event.") + (startselftest + (gexp + #~(#t)) + "The handler for the startselftest event.") + (endselftest + (gexp + #~(#t)) + "The handler for the endselftest event.") + (battdetach + (gexp + #~(#t)) + "The handler for the battdetach event.") + (battattach + (gexp + #~(#t)) + "The handler for the battattach event.")) + +(define-syntax define-enum + (lambda (x) + (syntax-case x () + ((_ name values) + (let* ((datum/name (syntax->datum #'name)) + (datum/predicate (string->symbol + (format #f "enum-~a?" datum/name))) + (datum/serialize (string->symbol + (format #f "serialize-enum-~a" datum/name)))) + (with-syntax + ((predicate (datum->syntax x datum/predicate)) + (serialize (datum->syntax x datum/serialize))) + #'(begin + (define (predicate value) + (memq value values)) + (define serialize serialize-symbol)))))))) + +(define mangle-field-name + (match-lambda + ('name "UPSNAME") + ('cable "UPSCABLE") + ('type "UPSTYPE") + ('device "DEVICE") + ('poll-time "POLLTIME") + ('lock-dir "LOCKFILE") + ('power-fail-dir "PWRFAILDIR") + ('no-login-dir "NOLOGINDIR") + ('on-batery-delay "ONBATTERYDELAY") + ('battery-level "BATTERYLEVEL") + ('remaining-minutes "MINUTES") + ('timeout "TIMEOUT") + ('annoy-interval "ANNOY") + ('annoy-delay "ANNOYDELAY") + ('no-logon "NOLOGON") + ('kill-delay "KILLDELAY") + ('net-server "NETSERVER") + ('net-server-ip "NISIP") + ('net-server-port "NISPORT") + ('net-server-events-file "EVENTSFILE") + ('net-server-events-file-max-size "EVENTSFILEMAX") + ('class "UPSCLASS") + ('mode "UPSMODE") + ('stat-time "STATTIME") + ('stat-file "STATFILE") + ('log-stats "LOGSTATS") + ('data-time "DATATIME") + ('facility "FACILITY"))) + +(define (serialize-string field-name value) + #~(format #f "~a ~a\n" #$(mangle-field-name field-name) '#$value)) +(define serialize-symbol serialize-string) +(define serialize-integer serialize-string) +(define (serialize-boolean field-name value) + #~(format #f "~a ~a\n" + #$(mangle-field-name field-name) + #$(if value "on" "off"))) + +(define-maybe string) + +(define-enum cable '( simple smart ether usb + 940-0119A 940-0127A 940-0128A 940-0020B 940-0020C + 940-0023A 940-0024B 940-0024C 940-1524C 940-0024G + 940-0095A 940-0095B 940-0095C 940-0625A MAM-04-02-2000)) +(define-enum type '(apcsmart usb net snmp netsnmp dumb pcnet modbus test)) +(define-enum no-logon '(disable timeout percent minutes always)) +(define-enum class '(standalone shareslave sharemaster)) +(define-enum mode '(disable share)) + +(define-configuration apcupsd-configuration + (apcupsd (package apcupsd) "The @code{apcupsd} package to use.") + + (shepherd-service-name + (symbol 'apcupsd) + "The name of the shepherd service. You can add the service multiple times +with different names to manage multiple UPSes." + empty-serializer) + (auto-start? + (boolean #t) + "Should the shepherd service auto-start?" + empty-serializer) + (pid-file + (string "/run/apcupsd.pid") + "The file name of the PID file." + empty-serializer) + (debug-level + (integer 0) + "The logging verbosity. Bigger number means more logs. The source code +uses up to @code{300} as debug level value, so a value of @code{999} seems +reasonable to enable all the logs." + empty-serializer) + + (run-dir + (string "/run/apcupsd") + "The directory containing runtime information. You need to change this if +you desire to run multiple instances of the daemon." + empty-serializer) + + ;; General configuration parameters + (name + maybe-string + "Use this to give your UPS a name in log files and such. This is +particularly useful if you have multiple UPSes. This does not set the EEPROM. +It should be 8 characters or less.") + (cable + (enum-cable 'usb) + "The type of a cable connecting the UPS to your computer. Possible generic +choices are @code{'simple}, @code{'smart}, @code{'ether} and +@code{'usb}. + +Alternatively, a specific cable model number may be used: @code{'940-0119A}, +@code{'940-0127A}, @code{'940-0128A}, @code{'940-0020B}, @code{'940-0020C}, +@code{'940-0023A}, @code{'940-0024B}, @code{'940-0024C}, @code{'940-1524C}, +@code{'940-0024G}, @code{'940-0095A}, @code{'940-0095B}, @code{'940-0095C}, +@code{'940-0625A}, @code{'M-04-02-2000}.") + (type + (enum-type 'usb) + "The type of the UPS you have. + +@table @code +@item apcsmart +Newer serial character device, appropriate for SmartUPS models using a serial +cable (not an USB). + +@item usb +Most new UPSes are an USB. + +@item net +Network link to a master apcupsd through apcupsd's Network Information Server. +This is used if the UPS powering your computer is connected to a different +computer for monitoring. + +@item snmp +SNMP network link to an SNMP-enabled UPS device. + +@item netsnmp +Same as the SNMP above but requires use of the net-snmp library. Unless you +have a specific need for this old driver, you should use the @code{'snmp} +instead. + +@item dumb +An old serial character device for use with simple-signaling UPSes. + +@item pcnet +A PowerChute Network Shutdown protocol which can be used as an alternative to +an SNMP with the AP9617 family of smart slot cards. + +@item modbus +A serial device for use with newest SmartUPS models supporting the MODBUS +protocol. + +@end table") + (device + (string "") + "For USB UPSes, usually you want to set this to an empty string (the +default). For other UPS types, you must specify an appropriate port or +address. + +@table @code +@item apcsmart +Set to the appropriate @file{/dev/tty**} device. + +@item usb +A null string setting enables auto-detection, which is the best choice for +most installations. + +@item net +Set to @code{@var{hostname}:@var{port}}. + +@item snmp +Set to @code{@var{hostname}:@var{port}:@var{vendor}:@var{community}}. The +@var{hostname} is the ip address or hostname of the UPS on the network. The +@var{vendor} can be can be \"APC\" or \"APC_NOTRAP\". \"APC_NOTRAP\" will +disable SNMP trap catching; you usually want \"APC\". The @var{port} is +usually 161. The @var{community} is usually \"private\". + +@item netsnmp +Same as the @code{'snmp}. + +@item dumb +Set to the appropriate @file{/dev/tty**} device. + +@item pcnet +Set to @code{@var{ipaddr}:@var{username}:@var{passphrase}:@var{port}}. The +@var{ipaddr} is the IP address of the UPS management card. The @var{username} +and the @var{passphrase} are the credentials for which the card has been +configured. The @var{port} is the port number on which to listen for messages +from the UPS, normally 3052. If this parameter is empty or missing, the +default of 3052 will be used. + +@item modbus +Set to the appropriate @file{/dev/tty**} device. You can also leave it empty +for MODBUS over USB or set to the serial number of the UPS. + +@end table") + (poll-time + (integer 60) + "The interval (in seconds) at which apcupsd polls the UPS for status. This +setting applies both to directly-attached UPSes (apcsmart, usb, dumb) and +networked UPSes (net, snmp). Lowering this setting will improve the apcupsd's +responsiveness to certain events at the cost of higher CPU utilization.") + + ;; Configuration parameters used during power failures + (on-batery-delay + (integer 6) + "The time in seconds from when a power failure is detected until we react +to it with an onbattery event. The @code{'powerout} event will be triggered +immediately when a power failure is detected. However, the @code{'onbattery} +event will be trigger only after this delay.") + (battery-level + (integer 5) + "If during a power failure, the remaining battery percentage (as reported +by the UPS) is below or equal to this value, the apcupsd will initiate a +system shutdown. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation") + (remaining-minutes + (integer 3) + "If during a power failure, the remaining runtime in minutes (as calculated +internally by the UPS) is below or equal to this value, apcupsd will initiate +a system shutdown. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation") + (timeout + (integer 0) + "If during a power failure, the UPS has run on batteries for this many +seconds or longer, apcupsd will initiate a system shutdown. The value of 0 +disables this timer. + +@quotation Note +@code{battery-level}, @code{remaining-minutes}, and @code{timeout} work +in a conjunction, so the first that occurs will cause the initation of a +shutdown. +@end quotation") + (annoy-interval + (integer 300) + "The time in seconds between annoying users (via the @code{'annoyme} event) +to sign off prior to system shutdown. 0 disables.") + (annoy-delay + (integer 60) + "The initial delay in seconds after a power failure before warning users to +get off the system.") + (no-logon + (enum-no-logon 'disable) + "The condition which determines when users are prevented from logging in +during a power failure.") + (kill-delay + (integer 0) + "If this is non-zero, the apcupsd will continue running after a shutdown +has been requested, and after the specified time in seconds attempt to kill +the power. This is for use on systems where apcupsd cannot regain control +after a shutdown.") + + ;; Configuration statements for Network Information Server + (net-server + (boolean #f) + "If enabled, a network information server process will be started.") + (net-server-ip + (string "127.0.0.1") + "An IP address on which the NIS server will listen for incoming +connections.") + (net-server-port + (integer 3551) + "An IP port on which the NIS server will listen for incoming connections.") + (net-server-events-file + maybe-string + "If you want the last few EVENTS to be available over the network by the +network information server, you must set this to a file name.") + (net-server-events-file-max-size + (integer 10) + "The maximum size of the events file in kilobytes.") + ;; Configuration statements used if sharing a UPS with more than one machine + (class (enum-class 'standalone) + "Normally standalone unless you share an UPS using an APC ShareUPS card.") + (mode (enum-mode 'disable) + "Normally disable unless you share an UPS using an APC ShareUPS card.") + ;; Configuration statements to control apcupsd system logging + (stat-time + (integer 0) + "The time interval in seconds between writing the status file, 0 +disables.") + (log-stats + (boolean #f) + "Also write the stats as a logs. This generates a lot of output.") + (data-time + (integer 0) + "The time interval in seconds between writing the data records to the log +file, 0 disables.") + (facility + maybe-string + "The logging facility for the syslog.") + + ;; Event handlers + (event-handlers + (apcupsd-event-handlers (apcupsd-event-handlers)) + "Handlers for events produced by apcupsd." + empty-serializer)) + +(define (%apccontrol config) + (program-file + "apccontrol" + (match-record (apcupsd-configuration-event-handlers config) + <apcupsd-event-handlers> + ( killpower commfailure commok powerout onbattery offbattery mainsback + failing timeout loadlimit runlimit doreboot doshutdown annoyme + emergency changeme remotedown startselftest endselftest battdetach + battattach ) + #~(begin + (use-modules (ice-9 format) + (ice-9 match) + (ice-9 popen) + (srfi srfi-9) + #$@(apcupsd-event-handlers-modules + (apcupsd-configuration-event-handlers config))) + ;; Script dir depends on these, and the configuration depends on the + ;; script dir. To sever the cyclic dependency, pass the file names via + ;; environment variables. + (define conf (getenv "GUIX_APCUPSD_CONF")) + (define powerfail-file (getenv "GUIX_APCUPSD_POWERFAIL_FILE")) + + (define (err . args) + (apply format (current-error-port) args)) + (define (wall . args) + (system* #$(file-append util-linux "/bin/wall") (apply format #f args))) + (define (apcupsd . args) + (apply system* #$(file-append apcupsd "/sbin/apcupsd") "-f" conf args)) + (define (mail-to-root subject body) + (let ((port (open-pipe* OPEN_WRITE + "/run/privileged/bin/sendmail" + "-F" "apcupsd" + "root"))) + (format port "Subject: ~a~%~%~a~&" subject body) + (close-pipe port))) + (match (cdr (command-line)) + (((? string? cmd) name connected powered) + (let ((connected? (match connected + ("1" #t) + ("0" #f))) + (powered? (match powered + ("1" #t) + ("0" #f)))) + (match cmd + ("killpower" #$killpower) + ("commfailure" #$commfailure) + ("commok" #$commok) + ("powerout" #$powerout) + ("onbattery" #$onbattery) + ("offbattery" #$offbattery) + ("mainsback" #$mainsback) + ("failing" #$failing) + ("timeout" #$timeout) + ("loadlimit" #$loadlimit) + ("runlimit" #$runlimit) + ("doreboot" #$doreboot) + ("doshutdown" #$doshutdown) + ("annoyme" #$annoyme) + ("emergency" #$emergency) + ("changeme" #$changeme) + ("remotedown" #$remotedown) + ("startselftest" #$startselftest) + ("endselftest" #$endselftest) + ("battdetach" #$battdetach) + ("battattach" #$battattach) + (_ + (err "Unknown event: ~a~%" cmd) + (err "Iff the event was emitted by apcupsd, this is a bug.~%") + (err "Please report to [email protected].~%") + (exit #f))))) + (args + (err "Unknown arguments: ~a~%" args) + (err "Iff the arguments were passed by apcupsd, this is a bug.~%") + (err "Please report to [email protected].~%") + (exit #f))))))) + +(define (apcupsd-script-dir config) + (computed-file + "apcupsd-script-dir" + #~(begin + (mkdir #$output) + (chdir #$output) + (symlink #$(%apccontrol config) "apccontrol")))) + +(define (apcupsd-config-file config) + (let ((run-dir (apcupsd-configuration-run-dir config))) + (mixed-text-file + "apcupsd.conf" + "\ +## apcupsd.conf v1.1 ## +# +# for apcupsd - GNU Guix +# +# \"apcupsd\" POSIX config file (generated by apcupsd-service-type) +" + (serialize-configuration config apcupsd-configuration-fields) + ;; This one is confusing. The manual page states: + ;; + ;; > It must be changed when running more than one copy of apcupsd on the + ;; > same computer to control multiple UPSes. + ;; + ;; However would you not want the lock to be per-device, not per-process? + ;; I decided to follow the documentation, but I do not understand why it + ;; should be like this. I do not have multiple UPSes to try. + (serialize-string 'lock-dir (string-append run-dir "/lock")) + (serialize-string 'power-fail-dir run-dir) + (serialize-string 'no-login-dir run-dir) + (serialize-string 'stat-file (string-append run-dir "/apcupsd.status")) + "SCRIPTDIR " (apcupsd-script-dir config) "\n"))) + +(define (apcupsd-activation config) + (match-record config <apcupsd-configuration> (run-dir) + #~(begin + (use-modules (guix build utils)) + (mkdir-p #$(string-append run-dir "/lock"))))) + +(define (apcupsd-shepherd-services config) + (match-record config <apcupsd-configuration> + ( apcupsd pid-file debug-level run-dir + shepherd-service-name auto-start?) + (let ((config-file (apcupsd-config-file config))) + (list + (shepherd-service + (documentation "Run the apcupsd daemon.") + (requirement '(user-processes)) + (provision (list shepherd-service-name)) + (auto-start? auto-start?) + (start #~(make-forkexec-constructor + '(#$(file-append apcupsd "/sbin/apcupsd") + "-b" ;do not daemonize + "-f" #$config-file + "-P" #$pid-file + "-d" #$(number->string debug-level)) + #:log-file + #$(format #f "/var/log/~a.log" shepherd-service-name) + #:environment-variables + (cons* (string-append "GUIX_APCUPSD_CONF=" + #$config-file) + #$(string-append "GUIX_APCUPSD_POWERFAIL_FILE=" + run-dir "/powerfail") + (default-environment-variables)))) + (stop #~(make-kill-destructor)) + (actions (list (shepherd-configuration-action config-file)))))))) + +(define (apcupsd-pam-extensions config) + ;; The apcupsd can be configured to prevent users from logging in on certain + ;; conditions. This is implemented by creation of a "nologin" file, and + ;; using a pam nologin module to prevent the login (if the file exists). + (define pam-nologin + (pam-entry + (control "required") + (module "pam_nologin.so") + (arguments (list (string-append "file=" + (apcupsd-configuration-run-dir config) + "/nologin"))))) + + (list (pam-extension + (transformer + (lambda (pam) + (pam-service + (inherit pam) + (auth (cons pam-nologin (pam-service-auth pam))))))))) + +(define apcupsd-service-type + (service-type + (name 'apcupsd) + (description "Configure and optionally start the apcupsd.") + (extensions (list (service-extension activation-service-type + apcupsd-activation) + (service-extension shepherd-root-service-type + apcupsd-shepherd-services) + (service-extension pam-root-service-type + apcupsd-pam-extensions))) + (default-value (apcupsd-configuration)))) |